Synthes distal fibula inventory. An Ankle Fusion Plating module is included to address ankle fusion man...

2.7 mm/3.5 mm LCP Lateral Distal Fibula Plate 12 Technique for

02.112.138 - SYNTHES 2.7MM/3.5MM LCP LATERAL DISTAL FIBULA PLATE, STAINLESS STEEL, 86MM, RIGHT. SYNTHES 02.112.138 $ 395.00 $ 395.00 $ 395.00. Add to wishlist. Get notification as soon as the product is available again. ...The CONDUIT™ Interbody Platform is a comprehensive portfolio of 3D-printed porous titanium interbody devices intended to stabilize the spinal segment, restore intervertebral height and to facilitate interbody fusion in the cervical (C2-T1) and lumbar spine (L2-S1) and are designed to mimic the published properties of bone. 1.Synthes Medical Pvt. Ltd., Established in 2006 at Gurugram in Haryana, is a leading Importer,Supplier,Trading Company of Orthopedic Implants in India. Synthes Medical Pvt. Ltd. is one of Trade India's verified and trusted sellers of listed products. With extensive experience in supplying and trading Distal Fibula Plates, Synthes Medical Pvt. Ltd. has made a reputed name for itself in the ...and rotation of the distal fragment. To place the plate in a posterior lateral position, an incision more posterior to the fibula may be made. Individual patient anatomy should be assessed, as some bending of the straight plate may be required. Bending of the distal lateral fibula plate, straight fibula plate, or the one third tubular plate can be2ePuy D Synthes 3.5 mm LCP® Clavicle Hook Plates Surgical Technique 3.5 mm LCP Clavicle Hook Plates The 3.5 mm LCP® Clavicle Hook Plate provides fixation for lateral clavicle fractures and for acromioclavicular joint injuries. 12º bend in shaft Undercuts in shaft reduce eases implant placement impairment of blood supplyLCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119.Opening the Distal Femur 1 Position Patient Position the patient supine on a radiolucent table. The knee of the injured leg should be fl exed 30° – 40°. A leg roll may be used to allow proper reduction and stabiliza-tion of the fracture. Position the image intensifi er to allow visualization of the proximal and distal femur in AP and ...Synthes 3 The Dynamic Condylar Screw is designed to provide strong and stable internal fixation of certain distal femoral and subtrochanteric fractures, with minimal soft tissue irritation. Strong The DCS plates are made of 316L stainless steel and are cold-worked for strength. Stable The two holes closest to the barrel accept 6.5 mm cancellousA number of high-profile firms and startups have set up logistics networks in India in the last decade as they attempt to digitize neighborhood stores. Bangalore-headquartered star...Stick to these simple actions to get Synthes Lc Dcp Small Frag Inventory completely ready for sending: Get the form you want in the collection of legal templates. Open the document in the online editor. Read through the recommendations to learn which data you need to include. Choose the fillable fields and include the requested info.synthes.vo.llnwd.netInventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010- Frakturen bei Knochen von kleinerer Größe, z. B. Fibula, Humerus und Ulna. LC-DCP-Platte 3,5, DCP-Platte 3,5, T-Platte 3,5 - Frakturfixierung und Fixierung beispielsweise nach Osteotomien, Fehlheilung, Pseudarthrose, insbesondere von distalem Radius, proximaler und distaler Tibia, proximalen Humerus und Klavikula.Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): Inventory Control Form 2.7 mm/3.5 mm LCP® Distal Fibula Plate System 2.4 mm Locking Screws, ... Inventory, Synthes, Inventory control form synthes, Inventory control form. INVENTORY CONTROL FORM - synthes.vo.llnwd.net synthes.vo.llnwd.net. 2 Stainless Steel Implants ...a fractured distal ulna that compromises the distal radio-ulnar joint, the ulnar column must be stabilized as well. 3. D.A. Rikli, P. Regazzoni: "Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases." J Bone Joint Surg [Br] 78 (4): 588-592. 1996. 70º-90º. Radial column1. Perform fibula osteotomy. Create an incision laterally over the fibula. Curve the approach anteriorly, just distal to the tip of the fibula. Dissection to the bone is directed anteriorly. Using a sagittal saw, create an osteotomy 10 cm from the distal tip of the fibula. Resect approximately 1 cm of bone proximal to the first cut, creating a gap.4 DePuy Synthes 3.5 mm LCP ® Distal Humerus Plates Surgical Technique. AO Principles. In 1958, the AO formulated four basic principles, which . 1 4 2 3. 4_Priciples_03.pdf 1 05.07.12 12:08. 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique. AO PRINCIPLES. In 1958, the AO formulated four basic principles, whichTake a look at the many small business inventory software options that are now available in the marketplace to better manage your inventory. If you buy something through our links,...Quick steps to complete and e-sign Va ankle inventory online: Use Get Form or simply click on the template preview to open it in the editor. Start completing the fillable fields and carefully type in required information. Use the Cross or Check marks in the top toolbar to select your answers in the list boxes.Patients were included in the study if they had an unstable ankle fracture treated with ORIF of the distal fibula with plates and screws consisting of either a traditional one-third semitubular construct (Synthes, Paoli, PA) or a 2.7-mm minifragment construct with a standard 2.7-mm LCP plate or a 2.7-mm LCP adaption plate (Synthes, Paoli, PA ...Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 mm 214.830 30 mm 214.832 32 mm ...Anatomically Contoured Locking Plates with Compression. The Periarticular Locking Plate System aims to combine optimal fit with advanced locking technology to offer a system for the treatment of comminuted fractures or fractures where deficient bone stock or poor bone quality is a factor. Anatomy. Ankle.The Variable Angle (VA) LCP Clavicle Plate 2.7 System is the next generation of internal fixation for the clavicle designed to treat medial, lateral, and shaft fractures in different size clavicles for patients of small, medium, and large stature (Fig 1). The system was created in response to clinical challenges in the current treatment of fractures of the clavicle and is available in both ...Now, working with a Synthes Distal Radius Inventory takes not more than 5 minutes. Our state-specific online blanks and clear recommendations remove human-prone faults. Adhere to our simple steps to get your Synthes Distal Radius Inventory well prepared rapidly: Find the web sample in the library. Enter all necessary information in the ...The screw heads are always flush with plate surface within 30 degrees of screw trajectory variance to help reduce risk of soft tissue irritation. 3 The VA LCP Two-Column Distal Radius Plates are the best-selling radius plates of DePuy Synthes. The remaining 20% of cases may require the use of alternate implants depending on the complexity.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...synthes.vo.llnwd.netPlate features - Head of plate is low profile for minimal prominence on medial malleolus - 3.5 mm cortex and 4.0 mm cancellous bone screws sit flush with plate in the nonlocking portion of distal combiholes to minimize screw prominence - Rounded edges to minimize soft tissue irritation - Limited-contact shaft profile - Available in stainless steel or titanium Combi-holes in the shaft ...Part of the complete Synthes LCP Elbow Set LCP Olecranon Plate Variety of plates: - Left and right version - Choice of six lengths with 2, 4, 6, 8, 10 or 12 LCP combi-holes in the shaft Proximal portion of the plate with 8 locking holes allows to set a maximum number of locking screws. Guide block for easy and correct insertion Indications ...The A.L.P.S. Fibula plates feature Type 2 Anodized Titanium Alloy low profile, anatomically contoured implants. In distal fibula surgery where soft tissue coverage is at risk, these low profile plates are designed to minimize discomfort and soft tissue irritation matching the anatomy of the distal fibula, while still having the required strength.VA-LCP Posterolateral T-Plate 2.7. ON. VA-LCP Lateral Distal Fibula Plate 2.7. ON. VA-LCP Medial Distal Tibial Plate 2.7/3.5. ON. Please refer to the instructions for use for a …The Synthes Locking Compression Plates—T-Plates are intended to buttress metaphyseal fractures of the proximal humerus, medialtibial plateau and distal tibia. They are also for use in fixation of osteopenic bone and fixation of nonunions and malunions. The Synthes LCP Proximal Tibia Plate is intended for treatment of non-unions, malunions,Features & Benefits. LCP Combi-holes. Combi-holes in the shaft accept: 3.5 mm locking screws. 3.5 mm cortex screws. 4.0 mm cancellous bone screws. Multiple Screw Options. Five coaxial distal holes accept 2.4 mm and 2.7 mm locking and cortex screws to provide multiple screw options. Kirschner Holes.自費醫材查詢比價網,synthes va distal fibula inventory,synthes distal tibia t-plate,synthes lcp small frag inventory,Synthes 3.5 LCP,VA Ankle,AO VA foot,synthes va ankle,Synthes Tubular plateSlide the shaft of the Anterolateral Plate submuscu-larly along the lateral border of the tibia, beneath the ante-rior compartment muscles and neurovascular bundle. The optimal position of the distal plate F.A.S.T. Tabs in relation to the joint is approximately 2 mm from the anterior articular surface (Figure 13).The FibuLock fibular nail is a cutting-edge, biologically friendly treatment for ankle fractures. It is inserted into the fibula through a small incision and acts like an internal splint to stabilize the fracture during healing. This minimally invasive technique may reduce wound complications often associated with standard open reduction internal fixation (ORIF) …INVENTORY CONTROL FORM 3.5 mm LCP Distal Tibia T-Plate Implants (cont’d) Instruments 4.0 mm Cancellous Bone Screws, fully threaded LENGTH LENGTH 206.010 10 mm 206.012 12 mm 206.014 14 mm 206.016 16 mm 206.018 18 mm 206.020 20 mm 206.022 22 mm 206.024 24 mm 206.026 26 mm 206.028 28 mm 206.030 30 mm 206.032 32 mm 206.035 35 mm 206.036 36 mm 206 ...Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, …- The two angled locking holes distal to the plate head accept 3.5 mm locking screws or 3.5 mm conical screws, to secure the plate position. The hole angles allow the locking screws to converge with two of the three screws in the plate head. - Combi holes, distal to the angled locking holes, combine a DCU hole with a threaded locking hole.Trauma | March 2021. New VA-LCP Lateral Distal Fibula Plates in titanium and associated anatomic tray for the Universal Small Fragment System. Trauma Home. In 2013 the Variable Angle LCP Ankle Trauma 2.7/3.5 system was approved by the AO TC Trauma.Radiography revealed fractures of the distal third of the left tibia and fibula, but the ankle articular surfaces were intact ( Fig. 1 A and B). Therefore diagnosis of a closed fracture of the distal third of the left tibia and fibula (AO: 43-A3) was made. Initially, strategies for detumescence and symptomatic treatment were administered.The Synthes Locking Compression Plates—T-Plates are intended to buttress metaphyseal fractures of the proximal humerus, medial tibial plateau, and distal tibia. They are also for use in fixation of osteopenic bone and fixation of nonunions and malunions. The Synthes 4.5 mm LCP Proximal Tibia Plate is intended forLCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP Extra-articular Distal Humerus Plate LCP Hook Plate 3.5 LCP Locking Compression Plate LCP Low Bend Medial Distal Tibia Plates 3.5 mm LCP Medial Proximal Tibial Plate 3.5Under the scan conditions defined above, the DePuy Synthes Tibial Nail Advanced System is expected to produce a maximum temperature rise of 7 °C in 1.5 T and 2 °C in 3.0 T for 15 minutes of continuous scanning. In non-clinical testing, the image artifact caused by the device extends approximately 141 mm from the DePuy Synthes Tibial Nailsynthes.vo.llnwd.netObjectives: To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. Design: Retrospective. Setting: Urban University Level I Trauma Center. Patient/participants: All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were reviewed from our institutional orthopaedic trauma registry.Do you have home inventory? All home insurance claims require one, so why not spend a day preparing yours? Here's how to do it! Expert Advice On Improving Your Home Videos Latest V...synthes distal fibula inventory. synthes va elbow inventory. Create this form in 5 minutes! Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms. Get form. How to create an eSignature for the synthes non locking small frag inventory.The best jewelry inventory software can track stones, findings, and finished products, plus purchase ordering and more. See our top picks. Retail | Buyer's Guide REVIEWED BY: Meagh...The Variable Angle (VA) LCP Clavicle Plate 2.7 System is the next generation of internal fixation for the clavicle designed to treat medial, lateral, and shaft fractures in different size clavicles for patients of small, medium, and large stature (Fig 1). The system was created in response to clinical challenges in the current treatment of fractures of the clavicle and is available in both ...Under the scan conditions defined above, the DePuy Synthes Tibial Nail Advanced System is expected to produce a maximum temperature rise of 7 °C in 1.5 T and 2 °C in 3.0 T for 15 minutes of continuous scanning. In non-clinical testing, the image artifact caused by the device extends approximately 141 mm from the DePuy Synthes Tibial NailApproach. stack of blue towels under anterior ankle to elevate limb. mark out lateral malleolus, anterior and posterior borders of fibula, borders of Achilles. place dry lap over marked incision. exsanguinate limb and inflate tourniquet. incision ~6-8cm in length along posterolateral border of fibula.Move the image intensifi er to the distal femur, place the proximal end of the radiographic ruler at the skin mark, and take an AP image of the distal femur. Verify fracture reduction. Read nail length directly from the ruler image, selecting the measurement that places the distal end of the nail at, or just proximal to, the physeal scar, or theThe VariAx Fibula Locking Plate System represents a new generation of implant technology. Pre-contoured periarticular plate design with type II anodization. Low-profile plate design and reduced screw head prominence. K-wire holes in plate. Wide range of 3.5mm locking and non-locking screw lengths. Contact.An Ankle Fusion Plating module is included to address ankle fusion management. 7 plates families and 7 screw types are offered in the system, designed to treat both low and high energy fractures of the ankle. The all-in-one tray provides a solution for simple to complex injuries of the distal tibia and fibula.Tips on how to fill out, edit and sign Synthes va foot inventory online. How to fill and sign 103S How to edit T-Plates. ... The 2.7 mm/3.5 mm LCP Distal Fibula Plates are indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. ...slightly distal to the hinged part of the table to allow flexion of the knee during surgery. Avoid too strong a traction and a fully extended knee, as the forces of the gastrocnemius muscle would draw the distal fragment into recurvatum. This does not only make the reduction of the fracture difficult, but also endangers the popliteal artery and ...The information that must be reported on a synforms distal fibula inventory includes the patient's name and medical record number, date of the inventory, the size of the inventory, the type of synform used (e.g. standard, reverse, hybrid), the angle of the distal fibula, the location of the tibial tuberosity, the position of the fibula relative to the tibia, the presence or absence of any ...01. Edit your synthes compact ankle inventory online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a signature pad. 03. Share your form with others. Send va ankle inventory via email, link, or fax.Plaque LCP pour tibia distal antérolatéral de 3,5 Plaque LCP à crochet pour clavicule LCP Compact Foot / Compact Hand LCP Compact Hand LCP Compact Hand de 1,5 Plaque condylienne LCP de 4,5/5,0 DHHS LCP Plaques LCP pour radius distal Dia-Méta palmaire Plaques LCP pour fibula distale Plaques LCP pour humérus distalThe LCP™ Pilon Plate is part of the locking compression plate system and was designed with the following key features: Combi holes that combine a dynamic compression unit with a locking screw hole. Shaft holes that accept 3.5 mm locking screws, 3.5 mm cortex screws, and 4.0 mm cancellous bone screws. A distal portion and arms that may be ...The VariAx Fibula Locking Plate System represents a new generation of implant technology. Pre-contoured periarticular plate design with type II anodization. Low-profile plate design and reduced screw head prominence. K-wire holes in plate. Wide range of 3.5mm locking and non-locking screw lengths. Contact.Synthes manufactures surgical instruments intended to prepare the site and aid in implantation of Synthes implants. The adverse events/side effects are based upon the implant devices rather than the instruments. Specific adverse events/side effects for the Implants can be found in the respective Synthes implant instructions for use. Sterile deviceThe FIBULINK ® System is designed to enable precise, anatomic syndesmotic fixation to help restore the physiologic motion of the ankle following a …About This Product. The system consists of three plate types, each one available in left and right version: Lateral Plate. Shaft Plate. Medial Plate. The VA LCP Clavicle Plates are made up of stainless steel and titanium alloy. The holes of the plates accept 2.7 mm cortex screws, 2.7 mm VA locking screws and 2.7 mm metaphyseal compression screws.6 DePuy Synthes 3.5 mm LCP ® Hook Plate Surgical Technique. Clinical Cases. Case 2* – 61-year-old male – Open distal humerus fracture: right arm – Good bone quality – …The LCP Distal Fibula Plates are part of the Synthes locking compression plate system that merges locking screw technology with conventional plating techniques. The plates …Distal Humerus Plates Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal …In contrast, the capturing rates boosted to 76.4% and 71.5% when utilizing VA screws in the DePuy Synthes VA-LCP and the Biomet plate. The high-frequency uncaptured areas tended to concentrate on the rim of the posterolateral wall and were mainly distributed in the posterior 1/2 to 3/4 of the parallel position of the fibula head.Locking Distal Fibula Plates, Right QTY PRODUCT # HOLES PRICE LOT# UDI AR-9943BR-04 4 AR-9943BR-05 5 AR-9943BR-06 6 AR-9943BR-08 8 AR-9943BR-10 10 AR-9943BR-12 12 AR-9943BR-14 14 Locking Third Tubular Plates ... Inventory Control Form Author: Arthrex, Inc. Subject:The information that must be reported on a synforms distal fibula inventory includes the patient's name and medical record number, date of the inventory, the size of the inventory, the type of synform used (e.g. standard, reverse, hybrid), the angle of the distal fibula, the location of the tibial tuberosity, the position of the fibula relative to the tibia, the presence or absence of any ...The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical …The distal tibia plating system has been designed for versatile treatment of all distal tibial fracture patterns. The comprehensive plate ofering gives surgeons the freedom to choose the most appropriate surgical approach for each patient. The implants have been designed to specifically address each of the variable fracture patterns commonly ...a standard lateral approach to the distal fibula according to AO recommendations. ORIF was performed according to AO guidelines using a 3.5 mm lag screw and semi-tubular neutralization plate, as well as 3.5 mm cortical screws [41]. The syndesmotic stability was verified with the lateral hook test [49]. Group II required preoperative preparations.LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP Extra-articular Distal Humerus Plate LCP Hook Plate 3.5 LCP Locking Compression Plate LCP Low Bend Medial Distal Tibia Plates 3.5 mm LCP Medial Proximal Tibial Plate 3.5to expose the fibular fracture, the distal fibula, and the fibular diaphysis. A lateral incision directly over the fibula can accentuate plate prominence and the wound closure will be directly over the implant. Alternatively, make the incision along the posterolateral border of the fibula where there is more soft-tissue cove gae. rThe Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.The distal tibia plates are made of stainless steel and are an extension of the ankle fracture management system. Plates have been designed with concern for the thin soft tissues on the tibia and are low profile with 2.7 mm locking or non-locking screws in the distal portion of each plate. Medial, anterolateral, anterior, posterior and small rim plates complete the plating offering for the ...Posterolateral Anatomic Distal Fibula Plate, Right QTY PRODUCT # HOLES LENGTH PRICE LOT# UDI AR-8963APLR-04 4 75 mm AR-8963APLR-06 6 100 mm AR-8963APLR-08 8 126 mm AR-8963APLR-10 10 151 mm Accessories QTY PRODUCT # DESCRIPTION PRICE LOT# UDI AR-8943-01 Guidewire w/ Trocar Tip, .053 in (1.35 mm × 150 mm)The drill bit is removed, and a 3.5 mm × 150 mm stainless steel cortical pelvic screw (DePuy Synthes, Paoli, PA) is advanced in a retrograde fashion into the distal fibula. A 150-mm screw is routinely used as the length of the cortical screw allows for it to contour readily to the diaphysis of the fibula without fracture displacement expected ...The 2.7mm/3.5mm VA LCP® Ankle Trauma system is a comprehensive plating system, consisting of: Medial Distal Tibia Plates. Anteromedial Distal Tibia Plates. Anterolateral Distal Tibia Plates. Distal Tibia T- and L-Plates. Lateral Distal Fibula Plates. The plates are part of the DePuy Synthes Variable Angle Locking Compression (VA LCP) System ...02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a comprehensive plating system that merges variable angle locking screw technology with conventional plating techniques for fixation of the ankle when growth plates have fused. Product Specifications.Synthes Locking Small Fragment LCP Instrument and Implant Set, with Self-Tapping Screws (105.434) 3.5 mm Locking Screws, self-tapping, with StarDrive recess Catalog # Catalog # Total Length Quantity 212.101 10 mm 5 212.102 12 mm 5 212.103 14 mm 5 212.104 16 mm 5 212.105 18 mm 5 212.106 20 mm 5 212.107 22 mm 5 212.108 24 mm 56 DePuy Synthes 3.5 mm LCP ® Hook Plate Surgical Technique. Clinical Cases. Case 2* – 61-year-old male – Open distal humerus fracture: right arm – Good bone quality – Olecranon osteotomy required to repair distal humerus. Preoperative lateral Postoperative AP Postoperative lateral Preoperative lateral Postoperative AP Postoperative ...DESCRIPTION. The Titanium Cannulated Tibial Nail-Ex offers a variety of proximal and distal locking options for tibial fractures, allowing the surgeon to tailor fixation to the fracture pattern. The system has a universal design, allowing use on the left or right tibia. Product Specifications. How to Use This Product.Fibular allografts have recently been used in the repair of complex periarticular fractures of the proximal tibia and distal femur. Fibular allografts can be inserted in a variety of manners to achieve goals specific to each individual fracture pattern. ... A Synthes 4.5mm distal femoral locking plate was reduced to bone distally with a ...The VariAx Fibula Locking Plate System represents a new generation of implant technology. Pre-contoured periarticular plate design with type II anodization. Low-profile plate design and reduced screw head prominence. K-wire holes in plate. Wide range of 3.5mm locking and non-locking screw lengths. Contact.Page 43 The Expert Tibial Nail allows for a maximum compression of 7 mm. If more compression of the fracture gap is needed, the conventional backstroke technique is recommended. Page 44 Advance the compression screw until the fracture gap is re- duced. Monitor reduction under image intensification.Gather AI, a startup using drones and software to sell inventory management services to warehouse operators, has raised $10 million. Gather AI, a startup using drones to inventory ...Predicate Device: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates Synthes One Third Tubular LCP Plate Device Description: Synthes 2.7 mm/3.5 mm LCP Distal Fibula Plates are contoured to match the anatomy of the distal fibula and diaphyseal region. The plates feature a low-profile design and Combi holes (DynamicOpening the Distal Femur 1 Position Patient Position the patient supine on a radiolucent table. The knee of the injured leg should be fl exed 30° - 40°. A leg roll may be used to allow proper reduction and stabiliza-tion of the fracture. Position the image intensifi er to allow visualization of the proximal and distal femur in AP and ...Synthes has established the performance and safety of the Universal Small Frag-ment System, and that they represent state of the art medical devices for surgical treatment and stabilization of fractures in various anatomical regions when used in conjunction with plates implants and according to their instructions for use and labeling.The VA LCP™ Ankle Trauma System 2.7/3.5 is part of Synthes Distal Tibia Plates family and consists of the following systems: VA LCP Medial Distal Tibial Plate 2.7/3.5. VA LCP Anteromedial Distal Tibial Plate 2.7/3.5. VA LCP Anterolateral Distal Tibial Plate 2.7/3.5. VA LCP Posterolateral L- and T-Plates 2.7. Get in Touch with a Sales Consultant.. LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula PlaThe Acutrak 2 - 7.5 is available in sizes from 2 DePuy Synthes 2.4 ®mm Variable Angle LCP Distal Radius System Surgical Technique. 2.4 MM VARIABLE ANGLE LCP DISTAL RADIUS SYSTEM. Plate features. Three head sizes accommodate . patient anatomy. • Narrow – 6-hole head (19.5 mm) • Standard – 6-hole head (22 mm) – 7-hole head (25.5 mm) • Anatomically contoured volar distalPlease contact your sales consultant for items approved for sale in Canada. VALCPDISRADPLATICF001 04/22. Open the catalog to page 1. Inventory Control Form Variable Angle LCP Distal Radius Plates Implants (cont’d) 2.4 mm VA LCP Volar Rim Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column … • Eight distal locking holes accept 2.7 mm cortex, Tips on how to fill out, edit and sign Synthes va foot inventory online. How to fill and sign 103S How to edit T-Plates. ... The 2.7 mm/3.5 mm LCP Distal Fibula Plates are indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone. ...CONFIBOTT | DePuy Synthes Pro-Pak® ® Fibula - One-Third Tubular 1 Plate, up to 7 Screws total and 1 Drill Bit CONFIBLCP | DePuy Synthes Pro-Pak Fibula - LCP 1 Plate, up to 10 Screws total and up to 2 Drill Bits total CONFIBVA | DePuy Synthes Pro-Pak Fibula - VA 1 Plate, up to 10 Screws total and up to 2 Drill Bits total FOOT the following DePuy Synthes extraction sc...

Continue Reading