40mbcq12. A maximum two (2) AHUs can be added to a MZ system...

PERFORMANCE™ SERIES 38MA*R OUTDOOR UNITS SPECIFICATIONS: 38M

Line Length. Additional Charge >25ft. Max. Lift. MCA / MOCP. Recommended Fuse Size. Maximum Maximum Heating BTU's Heating BTU's at -40F at 50F At 69°F Indoor DB. Maximum Maximum Cooling BTU's Cooling BTU's at 1130F at 1220F At 75.2°F Indoor DB. This sheet is not intended to replace the Installation Instructions.48,000 BTU 22.4 SEER 4-Zone Heat Pump System 12+12+12+24 - Casette. 2DF5509C-90FE-4762-BEB1-4913193A4FE9. Out of StockPrevious 40MBCQ12---3. 40MBCQ12---3. DLS HP CASSETTE 12K 208/230-1. Page Loading... Mouse over image to zoom, click to enlarge. Description: DLS HP CASSETTE 12K 208/230 1 PERFORMANCE SERIES. Status: Stocked. Log In for Pricing and Availability . Add to Wish ListHigh Wall Heat Pump Ductless System Indoor Model: Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Date: 9 Face Area Sq. Ft. 2.19Overview. The Performance 96 gas furnace is a two stage furnace, with a variable-speed blower motor and will run in low stage up to 90% of the time. Longer, low-stage run times give you better energy efficiency, better temperature control and increased comfort. It also assures you quieter performance.Refer to Fig. 13 and proceed as follows: Pump the system down to 1500 microns and allow the pump to continue operating for an additional 15 minutes. Close the service valves and shut off the vacuum pump. Connect a dry nitrogen cylinder and regulator to the system and break vacuum until the system reaches 2 psig.48K Outdoor Ductless HP Multi Zone Performance 208/230V R410A Zone 1 Indoor Model: 12K Cassette Ductless Indoor HP Performance 208/230V R410ALooking for Guide Information documents and more? Product iQ offers professional level information and is free for most users. Join Product iQ. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. Phone number: 1-877-854-3577 — Email: [email protected] Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) the KSACN0701AAA became the standard controller but is backwards compatible with ...MONTHLY SPECIAL Versatile Comfort You Can Look Up ToIdeal for a converted space or room addition where ductwork is not available, the Preferred™ Series 40MBCQ Cassette fits comfortably over-head to deliver quiet, unobtrusive heating and cooling. It sensesIndoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity. 12,000: Cooling Cap. Range Min - Max 4,000~13000: SEER Heating Cap. Range Min - Max 5,000~13500 HSPF 10.6 COP (47°F) 3.67 Heating Rated Capacity (17°F) 8,700 Heating Maximum Capacity (17°F) 12,000 Heating Maximum Capacity (5°F) 12,0003 model number nomenclature rbq system type q = heat pump unit type r = outdoor unit not used outdoor unit 38 mg 318 38 = outdoor unit mg = all voltage 3 = 208/230-1-60 nominal capacity 18 - 1 1/2 tons 24 - 2 tons 30 - 2 1/2 tons 36 - 3 tons 48 - 4 tons maximum number of fan coil units thatDLS HP CDU 48K SINGLE ZONE 208/230-1. Log In for Pricing and Availability. 38MBRQ58A--3. DLS HP CDU 58K SINGLE ZONE 208/230-1. Log In for Pricing and Availability. 38MGHBQ24CA3. DLS HP CDU 24K MULTI ZONE 208/230-1 HH. Log In for Pricing and Availability. 38MGHBQ30DA3.40MBCQ. Small but mighty, the 40MBCQ Cassette ductless indoor unit works quietly overhead and out of the way, providing efficient heating and cooling. Three fan speeds and a temperature-sensing handheld remote work together to place airflow right where you want it. It’s a convenient, versatile solution for both single and multi-zone systems.Equipment Parts List. There is no data available for this product. Need help with your order? 781-322-8800. 12K HP FCU HI WALL 208/230-1 PERFORMANCE.38mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---140MBCQ Cassette Ductless System Sizes 09 to 48 Installation Instructions NOTE: The images in this manual are for illustration purposes only. The actual model may differ slightly. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS36,000 BTU 21.5 SEER 3-Zone Heat Pump System 12+18+24 - Casette. 633DC5B0-C5A4-4222-A319-224DB1E04B32. Out of Stock40MBCAQ Cassette Preferred Series Sizes: 24 / 36 / 48 Select sizes are ENERGY STAR® certified based on outdoor unit pairing STANDARD FEATURES • Modes: Cool, Heat, Dry, Fan, Auto, Turbocool or warm your home with a bryant ® heat pump bryant offers real choices for efficient and reliable home comfort bryant.comThe temperature control range is 62 F to. 86 F (17 C to 30 C) in increments of 1 F or 1 C, and has a 46 F Heating Mode (Heating Setback). The wireless remote controller, has the ability to act as the temperature sensing location for room comfort. Model Number: 40MBCQ.Available in 208/230V. Modes: Cool, Heat, Dry, Fan, Auto. Auto-restart function. Louver control (fixed or swing) Three fan speeds. Follow Me (senses temperature at handheld remote) Heating Setback (46° F Heating Mode) Quiet indoor operation, as low as 34 decibels 1. Built-in condensate lift pump.Indoor Model 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 40MBCQ24---3 Outdoor Model 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 ENERGY STAR® YES YES YES NO Cooling System Tons 0.8 1.0 1.3 2.0 Cooling Rated Capacity Btu/h 9,000 12,000 16,000 24,000 Cooling Cap. Range Min - Max Btu/h 3,500~11,000 4,000~13000 4,500~18,000 8,500-26,500 SEER 20. ...Compatibility Table For matched compatibility see Product Data 40MPHAQ09XA3 40MPHAQ12XA3 40MAQB09B--3 40MAQB12B--3 40MAQB18B--3 40MAQB24B--3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 ...38mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---1† 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001.High Wall Heat Pump Ductless System Indoor Model: Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Date: 9 Face Area Sq. Ft. 2.19Ductless mini split systems can help you save up to 30% on your energy costs because they are more efficient than forced air systems, due to leaks and heat loss. Since mini splits have no ducts, they avoid the energy losses associated with ductwork of central forced air systems. 2.Carrier KSACN0701AAA is a 7- day programmable wired remote controller with LCD display which operates on Heat Pump, Cooling Only, Heating Only and Auto Modes. Wiring is done through 4-wire connectivity. Key Features. Weekly schedule 7 day programmable (Auto/Cool/Dry/Fan/Heat Mode) Follow Me default, temperature sensing on the controller.Indoor Model 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 Electrical Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 Power Supply Indoor unit powered from outdoor unit MCA A. 0.2 0.2 0.2 Controls Wireless Remote Controller (°F/°C Convertible) Standard Standard Standard38mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---1A maximum two (2) AHUs can be added to a MZ system. Refer to the application tables in the prodcut data for allowed combinations Regardless of size, when two (2) AHUs are connected to any MZ ODU, no other indoor units can be added to the system If a 30k or 36k AHU is connected to a any outdoor unit, 500g (17.6 Oz) of additional refrigerant ...Whatever the Challenge or Need, Ductless Technology Is the Solution Often called “mini-splits,” ductless systems use the same process for heating and coolingRevit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.Edition Date: 03/2018. SUBJECT TO CHANGE WITHOUT NOTICE. Catalog No: 40MBDQ-12-3-01SB. Page 1. Replaces: NEW. Construction View. Indoor Model: 40MBDQ12---3. Unit. inch. mm. OUTLINE. DIMENSIONS. A. 27.6.Available in 208/230V. Modes: Cool, Heat, Dry, Fan, Auto. Auto-restart function. Louver control (fixed or swing) Three fan speeds. Follow Me (senses temperature at handheld remote) Heating Setback (46° F Heating Mode) Quiet indoor operation, as low as 34 decibels 1. Built-in condensate lift pump.Indoor Unit 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 40MBCQ24---3 Outdoor Unit Single Zone* 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 Outdoor Unit Multi-Zone* 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--3 COMPATIBILITY: *Performance may vary based on the compatible …48,000 BTU 22.4 SEER 4-Zone Heat Pump System 9+9+12+12 - Casette. 31882068-3CC6-4A4C-8C3D-EE10E0433E5F. Out of StockCarrier Performance"' Console 1:1 Heat Pur Single Zone Quick Reference Guide High Heating Systems - 100% of Rated Capacity @ 50F I Nominal Cooling Capacity @ -130F38maqb12r--1; 38maqb09r--3 38maqb12r--3: 38maqb18r--3 38maqb24r--3: 38maqb30r--3 38maqb36r--3: 38mbrbq36aa3 38mbrbq48aa3: 38mbrq58a--3 38marbq12xa138marbq06xa3 38marbq09xa3 38marbq12xa3 38marbq18xa3 38marbq24xa3 38marbq30xa3 38marbq36xa3 38marbq36ab3 38mbrcq36aa3 38mbrcq48aa3 38mbrcq58aa3Find genuine OEM Carrier 40MBCQ12---301-- replacement parts at Parts Town with the largest in-stock inventory and same day shipping until 9pm ET.Whatever the Challenge or Need, Ductless Technology Is the Solution Often called “mini-splits,” ductless systems use the same process for heating and coolingDLS HP CDU 48K SINGLE ZONE 208/230-1. Log In for Pricing and Availability. 38MBRQ58A--3. DLS HP CDU 58K SINGLE ZONE 208/230-1. Log In for Pricing and Availability. 38MGHBQ24CA3. DLS HP CDU 24K MULTI ZONE 208/230-1 HH. Log In for Pricing and Availability. 38MGHBQ30DA3.Indoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity. 12,000: Cooling Cap. Range Min - Max 4,000~13000: SEER Heating Cap. Range Min - Max 5,000~13500 HSPF 10.6 COP (47°F) 3.67 Heating Rated Capacity (17°F) 8,700 Heating Maximum Capacity (17°F) 12,000 Heating Maximum Capacity (5°F) 12,000"The risks were right under the noses of the Fed," the Muddy Waters Research founder told Bloomberg about the turmoil that hit US regional banks. Jump to The Federal Reserve fueled...40MBCQ12---3 - 12000 Btuh Ductless Heat Pump Cassette.Compatibility Table For matched compatibility see Product Data 40MPHAQ09XA3 40MPHAQ12XA3 40MAQB09B--3 40MAQB12B--3 40MAQB18B--3 40MAHBQ06XA3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 40MBQB09C--3 40MBQB12C--340MBCQ12---3 40MBCQ18---3 619REQ012CBMA 619REQ018CBMA 619REQ009DBMA 619REQ012DBMA 619REQ018DBMA 619PEQ024BBMA DHMSHAQ24XA3 38MGRQ36D--3 Submittal Data MULTI-ZONE STANDARD FEATURES Features Outdoor: • Connect up to 4, multiple style indoor units High Wall Cassette Ducted Console Air Handler • 100% Heating Capacity at 5° F (-15° C)dhmphaq09xa3 dhmphaq12xa3 dhmshaq09xa3 dhmshaq12xa3 dhmshaq18xa3 dhmshaq24xa3 40mbcq09---3 40mbcq18---3 40mbfq12---3 40mphaq09xa3 40mphaq12xa3Standard. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) *24V interface compatible with all indoor units starting with Serial Number 4216V10001 unless …Indoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity 12,000 Cooling Cap. Range Min - Max 4,000~13000 SEER Heating Cap. Range Min - Max: 5,000~13500 HSPF: 10.6 COP (47°F) 3.67 Heating Rated Capacity (17°F) 8,700 Heating Maximum Capacity (17°F) 12,000DLS HP CASSETTE 48K 208/230 1 PERFORMANCE SERIES. Features / Benefits. STANDARD FEATURES. Sizes: 09 / 12 18 24 36 48; Available in 208/230V38maqb12r--1; 38maqb09r--3 38maqb12r--3: 38maqb18r--3 38maqb24r--3: 38maqb30r--3 38maqb36r--3: 38mbrbq36aa3 38mbrbq48aa3: 38mbrq58a--3 38marbq12xa138marbq06xa3 38marbq09xa3 38marbq12xa3 38marbq18xa3 38marbq24xa3 38marbq30xa3 38marbq36xa3 38marbq36ab3 38mbrcq36aa3 38mbrcq48aa3 38mbrcq58aa340mbcq12---3 40mbcq18---3 619req012cbma 619req018cbma 619req009dbma 619req012dbma 619req018dbma phased out indoor units 619req024dbma 619req009fbma 619req012fbma 619phaq12xa3 619peq009bbma 619peq012bbma 619peq018bbma 619req009cbma 619phaq09xa3 dhmshaq09xa3 dhmshaq12xa3 dhmshaq18xa3 40mbfq12---3 40mbfq18---3Find genuine OEM Carrier 40MBCQ12---301-- replacement parts at Parts Town with the largest in-stock inventory and same day shipping until 9pm ET. Skip to Navigation Skip to Content. Hi there, welcome to Parts Town! Parts Town and 3Wire have joined forces and teamed up with IPC, combining the team you know ...Indoor Model 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 40MBCQ24---3 Outdoor Model 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 ENERGY STAR® YES YES YES NO Cooling System Tons 0.8 1.0 1.3 2.0 Cooling Rated Capacity Btu/h 9,000 12,000 16,000 24,000 Cooling Cap. Range Min - Max Btu/h 3,500~11,000 4,000~13000 …PERFORMANCE™ SERIES 38MA*R OUTDOOR UNITS SPECIFICATIONS: 38MA*R Outdoor Unit Heat Pump System Size 12 9 12 18 24 30 36 Outdoor Model 38MAQB12R--1 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 38MAQB30R--3 38MAQB36R--3Shop for 12000 BTU Single Zone Mini-Split 208/230V from Carrier Corporation At Ferguson. Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and MRO products.Performance ™ series ductless systems offer that perfect balance between budget limits you may have today and your desire for energy savings and comfort options. The 40MAQ High Wall indoor unit can be matched with the 38MAR heat pump as part of the MA Single Zone System or matched with the 38MGR heat pump as part of the MG Multi-Zone System.Refer to Fig. 13 and proceed as follows: Pump the system down to 1500 microns and allow the pump to continue operating for an additional 15 minutes. Close the service valves and shut off the vacuum pump. Connect a dry nitrogen cylinder and regulator to the system and break vacuum until the system reaches 2 psig.dhmphaq09xa3 dhmphaq12xa3 dhmshaq09xa3 dhmshaq12xa3 dhmshaq18xa3 dhmshaq24xa3 40mbcq09---3 40mbcq18---3 40mbfq12---3 40mphaq09xa3 40mphaq12xa3Compatibility Table For matched compatibility see Product Data 40MPHAQ09XA3 40MPHAQ12XA3 40MAQB09B--3 40MAQB12B--3 40MAQB18B--3 40MAQB24B--3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 40MAHBQ24XA3 40MHHQ09---3Find genuine OEM Carrier 40MBCQ12---301-- replacement parts at Parts Town with the largest in-stock inventory and same day shipping until 9pm ET.Carrier36,000 BTU 21.5 SEER 4-Zone Heat Pump System 12+12+12+18 - Casette40MBCQ12---3 40MBCQ18---3 619REQ012CBMA 619REQ018CBMA 619REQ009DBMA 619REQ012DBMA 619REQ018DBMA 619PEQ024BBMA DHMSHAQ24XA3 38MGRQ36D--3 Submittal Data MULTI-ZONE STANDARD FEATURES Features Outdoor: • Connect up to 4, multiple style indoor units High Wall Cassette Ducted Console Air Handler • 100% Heating Capacity at 5° F (-15° C)30K Outdoor Ductless HP Multi Zone Performance 208/230V R410A Zone 1 Indoor Model: 12K Cassette Ductless Indoor HP Performance 208/230V R410A%PDF-1.6 %âãÏÓ 370 0 obj > endobj 395 0 obj >/Filter/FlateDecode/ID[]/Index[370 60]/Info 369 0 R/Length 107/Prev 310601/Root 371 0 R/Size 430/Type/XRef/W[1 3 1 ...Trust Technical Hot & Cold for the right OEM replacement part. Buy Carrier 11001010000063 Pump, Condensate new from the technical experts. Extensive product details, fast shipping, and expert supportFeb 28, 2024 · Description. The Carrier 38MAQ Mini Split Heat Pump System with Extreme Comfort Performance offer heating down to -22 degrees and cooling up to 130 degrees Fahrenheit. It’s one more way Carrier Ductless systems offer your customers indoor comfort solutions for any space, anytime of year. And with a full line of innovative systems offering a ...Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) *24V interface compatible with all indoor units starting with Serial Number 4216V10001 unless noted ...Overview. This compact ductless model is simple to install, only wires and piping need to run between the indoor and outdoor units. The 38MARB model also features premium energy efficiencies of 28.1 SEER2 and 12.4 HSPF2 making it a great choice for retrofit applications. California residents please see Proposition 65.40MBCQ. Small but mighty, the 40MBCQ Cassette ductless indoor unit works quietly overhead and out of the way, providing efficient heating and cooling. Three fan speeds and a temperature-sensing handheld remote work together to place airflow right where you want it. It’s a convenient, versatile solution for both single and multi-zone systems.Regardless of size, when two (2) AHUs are connected to any MZ ODU, no other indoor units can be added to the system. If a 30k or 36k AHU is connected to a any outdoor unit, 500g (17.6 Oz) of additional refrigerant charge has to be added to the system. 30k or 36k indoor units are not compatilble with phased out models.That marking or coloration marks pin 1. Make sure pin 1 on the ribbon cable is pointing towards pin 1 on both hard drives and also on the ATA controller card connector. Both hard drives will need a DC power connection. Normally the newer drive will need to be the master. Different BIOSs and ATA controllers can impact this.Temperature/Timer display This display is blank when Displays the set temperature by default, or timer setting set to AUTO speed or DRY mode. when using TIMER ON/OFF functions. Temperature range: 62-86 F. o. Timer setting range: 0-24 hours. This display is blank when operating in FAN mode. Fig. 5 − Unit Display.COMPATIBILITY CHARTS DUCTLESS SYSTEMS Indoor unit type AIR HANDLER Indoor Family Name Single Zone / Multi-zone 619PHA 619P*B 40MHH 619R*C 40MBCQ 619R*D 40MBDQ 619R*F 40MBFQ 40MBAACheck pg. 8 of the latest version of "Compatibility Charts" for updates regarding 24V interface incompatibility. The Carrier Infinity™ Ductless systems are shipped with a Wi-Fi kit standard.DUCTLESS SYSTEMS EXCEL SERIES 38MGR OUTDOOR UNIT OUTDOOR UNIT SPECIFICATIONS: 38MGR Outdoor Unit Heat Pump System Size 18 24 30 36 48 Outdoor Model 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--340MBCQ12---3. 38MGRQ24C--3. Submittal Data. MULTI-ZONE STANDARD FEATURES. Features Outdoor: • Connect up to 3, multiple style indoor units High Wall Cassette Ducted Console • 100% Heating Capacity at 5° F (-15° C) • Variable Speed (Inverter) Compressor • Basepan Heater factory installed40mbcq12---3 40mbcq18---3 619phaq09xa3 619phaq12xa3 619peq009bbma dhmshaq09xa3 619peq012bbma dhmshaq12xa3 619peq018bbma dhmshaq18xa3 619ahbq09xa3 dhmahbq09xa3 40mbfq24---3 40mbaaq24xa3 indoor unit high wall dhmphaq09xa3 dhmphaq12xa3 619peq024bbma dhmshaq24xa3 619ahbq06xa3 dhmahbq06xa3 40mhhq09---3 40mhhq12---3 40mhhq18---3 619req012cbma ...40MBCQ12---3 - 12000 Btuh Ductless Heat Pump Cassette.40MBCQ. chevron_leftchevron_right. Versatile Comfort You Can Look Up To. Ideal for a converted space or room addition where ductwork is not available, the Preferred™ Series 40MBCQ Cassette fits comfortably over-head to deliver quiet, unobtrusive heating and cooling.Modes: Cool, Heat, Dry, Fan, Auto Louver Control (Fixed or Swing) Outside Air Intake Built-in condensate Lift pump Follow Me (senses temperature at handheld remote)40MBCQ12---3 619REQ009CBMA 619REQ012CBMA Ducted: Console 40MBFQ12---3 619REQ009FBMA 619REQ012FBMA 40MBDQ09---3 40MBDQ12---3 40MBFQ09---3 619REQ012DBMA 619REQ009DBMA MULTI-ZONE STANDARD FEATURES Features Outdoor: • Connect 2, multiple style indoor units High Wall Cassette Ducted ConsoleDRILL A HOLE IN THE WALL FOR THE INTERCONNECTING PIPING, DRAIN AND WIRING. For maximum serviceability, it is recommended that you have the refrigerant line, flare connection and the drain connection on the outside of the wall so the fan coil can be mounted. Determine the pipe hole position. Drill the pipe hole.40MBCQ. Small but mighty, the 40MBCQ Cassette ductless indoor unit works quietly overhead and out of the way, providing efficient heating and cooling. Three fan speeds and a temperature-sensing handheld remote work together to place airflow right where you want it. It’s a convenient, versatile solution for both single and multi-zone systems.38mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---1619req012cbma 40mbcq12---3 619req018cbma 40mbcq18---3 40mbcq24---3 40mbcaq24xa3 40mbcq36---3 40mbcaq36xa3 40mbcq48---3 40mbcaq48xa3 40mccaq09xa3 40mccaq18xa3 619req009dbma 40mbdq09---3 40mbdaq09xh3 619req012dbma 40mbdq12---3 40mbdaq12xh3 619req018dbma 40mbdq18---3 40mbdaq18xh3 619req024dbma 40mbdq24---3 40mbdaq24xh340MBCQ12---3 2 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 19 4 MCA A. 0.2 Body Unit Width in (mm) 22.44 (570) Standard Body Unit Height in (mm) 10.24 (260) Optional Body Unit Depth in (mm) 22.44 (570) Cooling Indoor DB Min -Max °F(°C) 63~90 (17~32) Body Net Weight lbs (kg) 35.27 (16)Download this manual. 40MBCQ. Cassette Ductless System. Sizes 09 to 48. NOTE: The images in this manual are for illustration purposes. only. The actual model may differ slightly. NOTE: Read the entire instruction manual before starting the. installation.9.52*3 ) 12.5 R410A Heatin g Rated Ca p acit y (47°F ) Btu/h 23 ,000 Char g e lbs (k g) 6.17 (2.8 ) Heatin g Maximum Ca p acit y (5°F ) Btu/h 23 ,000 EEV. Visit our website at carrierductless.com PERFORMANCE™ SERIES 40MBC38mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a- High Wall Heat Pump Ductless System Indoor Model: Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Date: 12 Face Area Sq. Ft. 2.19Model Type of Document; 1: Intertek 157784 Manuals: Intertek Indoor Fireplace 157784 Fuel conversion instructions (4 pages) 2: Intertek 157785 Manuals Product Summary. Versatile Comfort You Can Indoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity 12,000 Cooling Cap. Range Min - Max 3,000~13,700 SEER Heating Cap. Range Min - Max 2,000~15,300 HSPF 10.6 COP (47°F) 3.22 Heating Rated Capacity (17°F) 8,250: Heating Maximum Capacity (17°F) 14,000 Heating Maximum Capacity (5°F) Heating Cap. Range Min - Max 12.7Regardless of size, when two (2) AHUs are connected to any MZ ODU, no other indoor units can be added to the system. If a 30k or 36k AHU is connected to a any outdoor unit, 500g (17.6 Oz) of additional refrigerant charge has to be added to the system. 30k or 36k indoor units are not compatilble with phased out models. Available in 208/230V. Modes: Cool, Heat, Dr...

Continue Reading